Calman Home supports direct calibration of Calman-Ready Samsung televisions. Using Samsung’s integrated calibration interface, Calman connects to the TV over a local network to automate grayscale, color, and gamma adjustments. This process ensures accurate, consistent image performance for both home entertainment.

Calman Required Version
- Calman Home v5.16.5 or higher
Hardware Requirements
- Calman Ready 2025 Samsung TV
| 4K QLED | 8K QLED | OLED | FHD/UHD | 
| QN90F | QN990F | S95F | F6000D | 
| QN90F | QN950F | S90F | 80U00F | 
| QN95F | QN900F | S90FD | U8000F | 
| QN85F | S85F | ||
| QN80F | |||
| QN70F | |||
| Q8F | |||
| Q7F | |||
| Q70F | |||
| Q6F | |||
| LS03F | 
Compatible 2020-2024 Models
| 2020 | 2021 | 2022 | 2023 | 2024 | 
| SQ950T | QN900A | QN900B | QN900C | QN900D | 
| SQ900T | QN800A | QN800B | QN800C | QN850D | 
| Q800T | QN700A | QN700B | QN700C | QN800D | 
| Q700T | WS1A (MicroLED) | QN100B | QN95C | QN95D | 
| Q95T | QN95A | QN95B | S95C | S95D | 
| Q90T | QN90A | S95B | S90C | QN90D | 
| Q80T | QN85A/Q80A | QN90B | QN90C | S90D | 
| Q70T | Q70A | QN85B | QN85C | QN85D | 
| The Frame | The Frame (LS03A) | Q80B | Q80C | S85D | 
| The Serif | The Sero | Q70B | Q70C | QN80D | 
| The Sero | The Terrace | The Serif (LS01B) | Q60C | Q80D | 
| Q60T | Q60A | The Frame (LS03B) | 32Q60C | Q70D | 
| TU8500 | Q60A 32” (US/EU) | The Sero (LS05B) | CU8000 | Q60D | 
| TU8000 | Q50A 32″ (US/EU) | Q60B | CU7000 | 32Q60D | 
| TU7000 | AU9000 | BU8000 (Except north America) | The Frame32 | 98″ DU9000 | 
| The Frame 32″ | AU8000 | BU7000 | 85DU8000 | |
| T5300/4300 | AU7700 | Frame32 (LS03BB) | DU8000 | |
| T5300/4300 (Europe) | AU7000 | DU7000 | ||
| T5500/4500 (SEA, SWA Voice) | The Serif (LS01D) | |||
| T5310/4310 (India) | The Frame (LS03D) | |||
| The Terrace (LST7T) | ||||
| HTS030 | ||||
| HTQ800 | 
Step 1
- From the Calman Menu in the top-left, choose Open Workflow Template -> Calman Ready and then Samsung.

- On the introduction screen, select your display type (LCD/OLED) and calibration mode (SDR/HDR) from the dropdown and click Next to proceed to Hardware Setup
Step 2

- Plug your meter into a USB port on the computer and press the Find Meter button on the left.
- When your meter is connected, select your display type from the dropdown
 
- Connect Pattern Source to your computer.
- Click the Find Source button, then select your source
- Select the pattern window size and delay
- QD-OLED
- SDR/HDR: Window 2%
 
- LCD/QLED
- SDR: Full 100%
- HDR: Window 10%
 
 
- QD-OLED
- Ensure your source is set to SDR or HDR corresponding to your choice in Step 1
- Set Pattern insertion
- Click the Reset to Defaults button to set the appropriate pattern insertion for the display and calibration type in Step 1
- LCD models do not require Pattern Insertion to be enabled.
 
 
- Click the Reset to Defaults button to set the appropriate pattern insertion for the display and calibration type in Step 1
 
- Click Next to proceed
Step 3
- Select the calibration targets
- Confirm/configure your calibration targets. These will be automatically set to common defaults by the options from Step 1
- Configuration Examples:
 
| SDR | HDR | 
|  |  | 
(Optional) Current State Measurements
- This workflow page is intended to document the monitor’s current operational state before establishing any DDC connection or selecting a calibration mode.
- This step can be skipped if documenting the current state is not needed. Another set of Pre-Calibration measurements will be taken in later steps.

- To take Current State Measurements, click the Measure button to measure the display’s grayscale and color response.
- Click Next to proceed
Step 4

- Connect your TV
-  On your TV:
- Enable IP Remote found under Connection > Network > Expert Settings > IP Remote > Enable
 
- Click the Find Display Button
- Select Samsung and your TVs year/model from the dropdown
- Enter the IP address assigned to the TV
- Settings > Connection > Network > Network Status > IP Settings
 
- Click Connect
- Accept the connection via the popup on the TV
 
 
- Enter the IP address assigned to the TV
 
-  On your TV:
Pre-Calibration Measurements
- This workflow page is intended to document the target picture mode prior to calibration.

- To take Pre-Calibration Measurements, click the Measure button to measure the display’s rayscale and color response.
- This will provide a point of reference to compare the calibration results
 
- Click Next to proceed
Step 5
- Here, the Calman picture mode will be reset to prepare for calibration.

- Select the Picture Mode for calibration
- Click the Reset button. This resets and prepares the picture mode for calibration.
- In the Samsung OSD
- Disable Color Booster (Settings > All Settings > Picture > Expert Setings > Color Booster Pro)
 
- Click Next to proceed
SDR Only – Measure and set Luminance
- Here, you can adjust the monitor’s Backlight setting to one that meets or exceeds your target luminance

- Click Measure and adjust the Backlight slider as needed.
- Click Next to proceed
Step 6
- On this page, Calman will adjust your display’s White Balance

- Click the AutoCal button to perform the 2pt greyscale AutoCal
- Click Next after AutoCal has completed to adjust the Multipoint Greyscale.

- Click the AutoCal button and select the correct data points in the AutoCal Dialog to auto-calibrate the Grayscale/Luminance response on the display.
- This should match the video range you chose in Step 1.
 
- Click OK to begin greyscale AutoCal.
- When AutoCal is complete, click the Next button to proceed.
Step 7
- On this page, Calman will calibrate the Color Management System.

- In the OSD on the Samsung TV, change the Color Space Settings to Custom
- Settings > All Settings > Picture > Expert Settings > Color Space Settings > Color Space
- Confirm the Color Adjustment point is set to 100%
 
- Press the AutoCal button to calibrate the TV’s CMS
- Settings: Saturation Set: 50% Saturation Point: 50% Stimulus Level: 50
- Multipoint CMS: In Cal-Day or Cal-Night modes, you may use Samsung’s Multipoint CMS feature. 
- When Multi-CMS is selected, a Multi-CMS saturation set should also be selected
 
 

- Click OK to begin the colorspace AutoCal process
- When AutoCal is complete, press the Next button to proceed
Step 8
- In this step, you’ll take measurements of the calibration results.

- To take Post-Calibration Measurements, click the Measure button to measure the display’s grayscale and color response.
- Click Next to proceed

- On the Calibration Complete page, you can choose to…
- Save 
- Select Save to save the session measurements for later reference
 
- View Comparison
- Displays Pre and Post Calibration measurements of the calibrated mode side-by-side
 
- Restart
- Returns to the beginning of the workflow where a new mode or colorspace can be selected
- Note: Does not save workflow data
 
 
- Save